DCM49A is a general purpose 3¾ digits AC/DC clamp meter with a backlight and an LCD display. The jaw opening is 60mm approx and can measure AC/DC up to 1000A. It also measures DC voltage-1000V, AC voltage-700V, resistance up to 40MΩ, frequency-10 MHz with duty cycle, continuity & diode measurements. This meter also has a capacitance range of up to 100µF & is powered by a 9V battery.
Application
FEATURES
Accuracy
General
Display : 4000 Counts, LCD display.
Dimensions (W x H x D) : 260 X 91 X 44.5mm approx.
Weight : 500g. approx.
Environmental
Operating Temperature : 0°C to 40°C <80% RH (non condensing)
Storage Temperature : – 10°C to 60°C <80% RH (non condensing)
Battery Removed
Temperature coefficient : 0.1 X Accuracy / deg C.
Power
Power Supply : 9V Battery NEDA 1604 / Type 6F22/006P
Auto Power OFF : 30 min of Ideal condition
consumption is 1.3mA approx. (Can be canceled by pushing any except for Hold & SELECT key before powering on the meter).
Safety : In accordance with IEC 61010-1 and IEC 61010-2-32, Double insulation
DC 1000V and AC 700V, CAT II and pollution degree II
Standard Accessories
Pair of Test Leads, User Manual, Battery installed
DC Voltage (Auto/Manual Ranging)
Range | Accuracy | Overload protection | Input Impedance |
4V | ±(1.5% + 10d) | 1000V DC OR 750 V AC RMS | 10MΩ approx. |
40V | |||
400V | |||
1000V |
AC Voltage (50-500Hz)Trms
Range | Accuracy | Overload protection | Input Impedance |
4V | ±(1.5% + 10d) | 1000V DC OR 750 V AC RMS | 10MΩ I I 30pF (approx.) |
40V | |||
400V | |||
700V |
DC/AC (50-60Hz) : (Manual Ranging
Range | Resolution | Accuracy | Overload protection |
400A | 0.1A | ±(2.5% + 10d) | 102% of Full scale for <60 Sec. |
1000A | 1A |
Resistance Range (Auto/Manual)
Range | Accuracy | Overload protection |
400 Ω | ±(1% + 5d) | 250V DC/AC RMS |
4 KΩ | ||
40 KΩ | ||
400 KΩ | ||
4 MΩ | ||
40 MΩ |
CAPACITANCE RANGE (Auto-Ranging)
Range | Accuracy | Overload protection | Open Circuit Voltage |
100 µF | ±(3.0% + 10d) | 250V DC or AC RMS | <0.8V |
Diode Test: Measure forward voltage drop. Evers circuit. Voltage approx. 1.5V Input protected up to 250V DC or AC RMS.
Continuity : Buzzer sound if resistance <50 Ohm
Input protected up to 250V DC or AC RMS.
FREQUENCY RANGES (Auto-Ranging Only)
Range | Accuracy | Sensitivity | Overload Protection |
10 MHz | ±(0.5% + 10d) | 4V | 250V RMS AC or DC |
DUTY CYCLE :
Range | Resolution | Sensitivity | Overload Protection |
0.1%-99.9% | 0.1% | 4V | 250V RMS AC or DC |
Note: Its use is not advised on multi-phase high energy circuits where heavy transients are likely to occur.
Motwane’s customer base is a testament to its ongoing ability to provide reliable, accurate, and long-lasting products, resulting in enduring relationships that are based on mutual satisfaction, loyalty, and trust.
Contact Us
It’s easy to switch to Motwane. Our specialists take care of all conceivable requirements your project may have. With over a 100 years of experience in delivering world-class projects, Motware is the right choice.
Enquire NowBook a demo
⨯