Motwane’s M65 dual display TRMS digital multimeter is specially designed in our research laboratory to measure precise results. It is manufactured under stringent manufacturing processes for R&D and process industries. M65 has a 6000 counts LCD dual display to measure facilities like capacitance, resistance, diode, and continuity along with µ Amp. range & DCV accuracy of 0.25%. M65 helps you troubleshoot and repair electrical and electronic systems. It is a high performance multimeter complying with IEC 61010-1 safety standards and with CE, CAT III 1000 V safety rating, and IP-54 protection. M65 is a design marvel with a robust and rugged double mold casing.
Application
Features
Accuracy
General
Display : 6,000 counts dual LCD display with a white backlight.
Display Update Rate : 2.8 times per second nominal.
Dimensions (WxHxD) : 94 X 205 X 36 mm approx.
Weight : 450g. approx.
Dual Display : For AC voltage with frequency & frequency with duty cycle simultaneously
Environmental
Operating Temperature : 0°C to 50°C
Relative Humidity : 80% RH @ 5°C to 31°C
50% RH @ 31°C to 40°C
non condensing
Storage Temperature: – 20°C to 60°C
Power
Power Supply : 9V Battery Type 6F22 or equivalent
Power Consumption : 8mA typical.
Low Battery Indication : ‘LO BAT’ is displayed below 6.5V approx.
Auto Power OFF : After 15 minutes, ideal sleep mode
consumption is 1.3mA approx. (Can be canceled by pushing any except for the Hold & SELECT key before powering on the meter).
Overload Protection
Fuse Protection for ‘µA’ & : 0.8 A/ 250V fast blow type ceramic fuse.
‘mA’ input terminal
Fuse Protection for 10A : 20A/ 500V fast blow type ceramic fuse
input terminal
Ω/ / / / /Hz(%) : 440 V DC / AC rms
Safety
Directives for CE Certification : LVD:2006/95/EC., EMC: 2004/104/EC
Measurement Category : CAT III, (1000V) Reinforced Insulation.
Relevant Standard Specification : EN 61010-1:2010, EN 61326-1:2006
IP Rating (Dust & Water Protection) : IP 54
Accessories
Standard Accessories
Pair of Test leads, User Manual, Battery installed, Fuses, Carry Bag.
Optional Accessories
Pair of Test Leads, Pair of small Test Leads
DC Voltage
Range | Resolution | Max. Reading | Accuracy | Overload protection |
6V | 1 mV | 6.000 V | ±(0.25% + 3) | 1050V DC/AC RMS |
60V | 10 mV | 60.00 V | ±(0.25% + 3) | |
600V | 100 mV | 600.0 V | ±(0.25% + 3) | |
1000V | 1 V | 1000 V | ±(0.5% + 3) |
Note: 1. Input Impedance 10MΩapprox.
AC Voltage (50-500Hz)Trms
Range | Resolution | Max. Reading | Accuracy | Overload protection |
6V | 1 mV | 6.000 V | ±(1% + 5) | 1050V DC/AC RMS |
60V | 10 mV | 60.00 V | ±(1% + 5) | |
600V | 100 mV | 600.0 V | ±(1% + 5) | |
1000V | 1 V | 1000 V | ±(1.2% + 8) |
Note: 1. Input impedance: 10 MΩ approx. shunted by 60pF approx.
DC Current Rang
Range | Resolution | Max. Reading | Accuracy | Overload protection |
600µA/6000µA | 0.1µA/1µA | 600.0µA/6000µA | ±(1.2% + 5) | 0.8A/ 250V DC/AC fuse protection |
60mA/600 mA | 10µA/100µA | 60.00mA/600.0 mA | ±(1.5% + 5) | |
10 A | 10 mA | 10.00 A | ±(1.5% + 8) | 20A/250V DC/AC fuse protection |
AC Current Range (50Hz-500Hz) Trms
Range | Resolution | Max. Reading | Accuracy | Overload protection |
600µA/6000µA | 0.1µA/1µA | 600.0µA/6000µA | ±(1.5% + 5) | 0.8A/ 250V DC/AC fuse protection |
60mA/600 mA | 10µA/100µA | 60.00mA/600.0 mA | ±(1.8% + 5) | |
10 A | 10 mA | 10.00 A | ±(2.0% + 8) | 20A/250V DC/AC fuse protection |
Note: The main display shows AC Current and the sub-display shows frequency applied.
Resistance Range
Range | Resolution | Max. Reading | Accuracy | Overload protection |
600 Ω | 0.1 Ω | 600.0 Ω | ±(0.5% + 3) | 440V DC/AC rms |
6 KΩ | 1 Ω | 6.000 Ω | ±(0.5% + 3) | |
60 KΩ | 10 Ω | 60.00 KΩ | ±(0.5% + 3) | |
600 KΩ | 100 Ω | 600.0 KΩ | ±(0.5% + 3) | |
6 MΩ | 1 KΩ | 6.000 MΩ | ±(1% + 5) | |
60 MΩ | 10 KΩ | 60.00 MΩ | ±(3% + 10) |
Note: 1. Open circuit voltage on 600Ω range is -3.3V DC approx.
2.Open circuit voltage on 6kΩ-6MΩ ranges is -1.10V DC approx.
3.Open circuit voltage on 60MΩ range is -600mV approx.
CAPACITANCE RANGE (Auto-Ranging Only)
Range | Resolution | Max. Reading | Accuracy | Overload protection |
6 nF | 0.001 nF | 6.000 nF | ±(5.0% + 10) | 440V DC/AC RMS |
60 nF | 0.01 nF | 60.00 nF | ±(3.0% + 10) | |
600 nF | 0.1 nF | 600.0 nF | ±(3.0% + 10) | |
6 µF | 1 nF | 6.000 µF | ±(3.0% + 10) | |
60 µF | 10 nF | 60.00 µF | ±(3.0% + 10) | |
600 µF | 100 nF | 600.0 µF | ±(5.0% + 10) | |
6 mF | 1 µF | 6.000 mF | ±(5.0% + 20) | |
60 mF | 10 µF | 60.00 mF | ±(5.0% + 30) |
Note: 1. Settling time on 6mF and 60mF range is 40 secs. approx.
Now apply low value capacitance.
Diode Test
Range | Resolution | Open Circuit Voltage | Test Current |
6V | 1mV | ≤3.0 V DC approx. | ≤2.0mA approx. |
Continuity Test
Range | Resolution | |
600.0Ω | 0.1Ω | Meter Beeps < 60Ω |
Note: Open Circuit Voltage on continuity range is -3.3VDC approx.
FREQUENCY RANGES (Auto-Ranging Only)
Range | Resolution | Max. Reading | Accuracy | Overload protection |
60 Hz | 0.01 Hz | 60.00 Hz | ±(0.5% + 3) | 1000V DC/AC RMS |
600 Hz | 0.1 Hz | 600.0 Hz | ±(0.5% + 3) | |
6 kHz | 1 HZ | 6.000 kHz | ±(0.5% + 3) | |
60 kHz | 10 Hz | 60.00 kHz | ±(0.5% + 3) | |
600 kHz | 100 Hz | 600.0 kHz | ±(0.5% + 3) | |
6 MHz | 1 kHz | 6.000 MHz | ±(0.5% + 3) | |
60 MHz | 10 kHz | 60.00 MHz | ±(0.5% + 3) |
Note: 1. The main display shows frequency & the sub-display shows the duty cycle.
DUTY CYCLE MEASUREMENT
Range | Resolution | Accuracy | Overload Protection |
0.1%-98.9% | 0.1% | ±(0.5% + 30) | 440V DC/AC RMS |
Accuracy is specified at <20 VAC rms
Sensitivity : 10Hz to 100 kHz > 200mVrms,
1000 kHz to 10MHz > 2Vrms
Electromagnetic compatibility: In RF Field, overall accuracy is equal to 10% of reading +30 digits
Motwane’s customer base is a testament to its ongoing ability to provide reliable, accurate, and long-lasting products, resulting in enduring relationships that are based on mutual satisfaction, loyalty, and trust.
Contact Us
It’s easy to switch to Motwane. Our specialists take care of all conceivable requirements your project may have. With over a 100 years of experience in delivering world-class projects, Motware is the right choice.
Enquire NowBook a demo
⨯